Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Warning
iconfalse
titleImportant

This is enabled for Hearts (AHG1) that have been updated to FW 1.3.15 or later only. For previous versions you have to use the old factory reset process (alternative B). 


|| Watch the video tutorial on how to factory reset the Heart with the power cable: https://youtu.be/WMY0kyBib8E


  1. Unplug the power cable and plug it back again to start the different boot-stages. 

    Boot stages on first boot: (a) Light blue → (b) Dark blue → (c) Orange → (d) Light blue → (e) Dark blue

  2. Wait until the boot stage reaches (c), Orange LED-light, and unplug at this stage. 
  3. Plug the power cable back in and wait until the boot stage reaches (c) again, Orange LED-light, and unplug at this stage
  4. Plug the power cable back in and wait until the boot stage reaches (c) again. This time the LED-light will show Red. Unplug again at this stage.
  5. Plug the power cable back in one last time and wait for the factory reset process to start. Factory reset has started successfully if the LED-light shows Red and then shifts to Orange (blinking). 
  6. Wait for up to 20 minutes until the reset is finished. Once finished, the LED-light will show the default Dark blue in stage (e).   
  7. After the reset your Heart will have a version called LITE. The LITE version will automatically retrieve and update to the latest version once you start installing the Animus Heart again.

...